Comparative analysis of ON-SPOT and TOP-SPOT

Comparative analysis of ON-SPOT and TOP-SPOT

AUTN On-Spot1 AUTN Top-Spot
Demand «ON-SPOT petroleum products loading system(telescopic) «TOP-SPOT petroleum products loading system" (hinged)
1. Reliability worse better
2. Cost comparable comparable
3. Diameter of filling pipe (performance) up to 300 mm (above) usually up to 200 mm.
4. Tightness better worse
5. Security (AUTN-96 requirements) ** perform under certain conditions no

* The neck of the tank when filled is lowered by 5-10 cm. The telescopic tube has a clamping slab that descends under its own weight. On the hinge pipe, the clamping plate is performed with a single design with the pipe and this is not possible, depressurization occurs.

** When filling, it is necessary to lower the pipe to the bottom of the tank (5-7 cm), then the filling capacity should be slowly "in the trapezoidal form" increases from 20 to 100% so that there is no falling jet, which can form a static discharge of electricity. When filling 8 axle tanks with a hinge pipe, this is not provided. The tank fleet consists of 90% of 4-axle tanks, the diameter of which is 3000 mm.

If you have a pipe of a certain length with a fixed plate, then for tanks with a diameter of 3200 mm (8-axle) there will be a falling stream. c. proper sliding or tightness is not ensured. It is recommended to use a stainless insert (exclude spark formation) between the neck and the pipe, but this complicates the design.

The main difference between “ON-SPOT” and “TOP-SPOT” is the filling pipe. The filling pipe "ON-SPOT" is telescopic, and the "TOP-SPOT" has a filling pipe on the hinges, the vapor selection pipe, similar to the pipe for products, is made on hinge connections and is lowered simultaneously in a single mechanism.